USED Fluke 810 Vibration Tester - Calibrated

The Fluke 810 Vibration Tester is the most advanced troubleshooting tool for mechanical maintenance teams who need an answer now. The unique diagnostic technology helps you quickly identify and prioritize mechanical problems, putting the expertise of a vibration analyst in your hands.The Fluke 810 Vibration Tester puts you one step ahead by coupling a powerful diagnostic engine with a simple step-by-step process to report on specific machine faults and their severity the first time measurements are taken, without prior measurement history. Overall vibration measurements and spectral diagrams give technicians the ability to quickly asses overall machine health, while actionable recommendations give you the confidence you need to address critical problems first. You take pride in your facility, your team, and your work.
$2,410.00
Qty:
The Fluke 810 Vibration Tester is the most advanced troubleshooting tool for mechanical maintenance teams who need an answer now. The unique diagnostic technology helps you quickly identify and prioritize mechanical problems, putting the expertise of a vibration analyst in your hands.

You take pride in your facility, your team, and your work. You do what it takes to keep things up and running, but sometimes there is not enough time or resources to keep up with the workload, let alone be proactive about mechanical maintenance. The Fluke 810 Vibration Tester puts you one step ahead by coupling a powerful diagnostic engine with a simple step-by-step process to report on specific machine faults and their severity the first time measurements are taken, without prior measurement history. Overall vibration measurements and spectral diagrams give technicians the ability to quickly asses overall machine health, while actionable recommendations give you the confidence you need to address critical problems first.

Use the Fluke 810 Vibration Tester to:

-Troubleshoot problem equipment and understand the root cause of failure
-Survey equipment before and after planned maintenance and confirm the repair
-Commission new equipment and ensure proper installation
-Provide quantifiable proof of equipment condition and drive investment in repair or replacement
-Prioritize and plan repair activities and operate more efficiently
-Anticipate equipment failures before they happen and take control of spare parts inventories
-Train new or less-experienced technicians and build confidence and skill across the team

Key Features

- On-board identification and location of the most common mechanical faults (bearings, misalignment, unbalance, looseness) focus maintenance efforts on root cause, reducing unplanned downtime
- Overall vibration level allows you to quickly assess overall machine health directly from the diagnosis screen
- Fault severity scale with four severity levels helps you prioritize maintenance work
- Repair recommendations advise technicians on corrective action
- Detailed diagnostic reports and spectral diagrams help confirm data quality, and narrow down the root cause of failures
- On-board context sensitive help provides real-time tips and guidance to new users

Specs: Fluke 810 Vibration Tester

Diagnostic Specifications

Standard Faults
Unbalance, looseness, misalignment and bearing failures

Analysis For
Motors, fans, blowers, belts and chain drives, gearboxes, couplings, centrifugal pumps, piston pumps, sliding vane pumps, propeller pumps, screw pumps, rotary thread/gear/lobe pumps, piston compressors, centrifugal compressors, screw compressors, closed coupled machines, spindles

Motor Rotational Speed Range
200 rpm to 12000 rpm

Diagnosis Details
Plain-text diagnosis, fault severity (slight, moderate, serious, extreme), repair details, cited peaks, spectra

Electrical Specifications

Ranging
Automatic

A/D Converter
4 channel, 24 bit

Usable Bandwidth
2 Hz to 20 kHz

Sampling
51.2 Hz

Digital Signal Processing Functions
Automatically configured anti-alias filter, high-pass filter, decimation, overlapping, windowing, FFT, and averaging

Sampling Rate
2.5 kHz to 50 kHz

Dynamic Range
128 dB

Signal To Noise Ratio
100 dB

FFT Resolution
800 lines

Spectral Windows
Hanning

Frequency Units
Hz, orders, cpm

Amplitude Units
in/sec, mm/sec, VdB (US), VdB* (Europe)

Non-volatile Memory
SD micro memory card, 2 GB internal user accessible slot for additional storage

General Specifications

Dimensions (H x D x W)
18.56 x 7.00 x 26.72 cm (7.30 x 2.76 x 10.52 in)

Weight (With Battery)
1.9 kg (4.2 lb)

Display
¼ VGA, 320 × 240 Color (5.7 inch diagonal) TFT LCD with LED backlight

Input/Output Connections
Triaxial sensor connection > 4 pin M12 connector
Single axis sensor connection > BNC connector
Tachometer Connection > Mini DIN 6 pin connector
PC Connection    Mini ‘B’ USB (2.0) connector
Battery    Battery type > Lithium-ion, 14.8 V, 2.55 Ah
Battery charging time > Three hours
Battery discharge time > Eight hours (under normal conditions)

AC Adapter
Input voltage    100 VAC to 240 VAC
Input frequency    50/60 Hz

Operating System
WinCE 6.0 Core

Language Support
English, French, German, Italian, Japanese, Portuguese, Simplified Chinese, Spanish

Warranty
Three-years

Environmental Specifications

Operating Temperature
0°C to 50°C (32°F to 122°F)

Storage Temperature
-20°C to 60°C (-4°F to 140°F)

Operating Humidity
10% to 95% RH (non-condensing)

Agency Approvals
CHINA RoHS, CSA, CE, C TICK, WEEE

Electromagnetic Compatibility
EN 61326-1:2006, EN 61010:1:2001 2nd ed.

Sensor Specifications

Sensor Type
Accelerometer

Sensitivity
100 mV/g (±5%, 25°C)

Acceleration Range
80 g peak

Amplitude Nonlinearity
1%

Frequency Response
Z    2 - 7,000 Hz ±3dB
X, Y    2 - 5,000 Hz ±3dB

Power Requirement (IEPE)
18 VDC to 30 VDC, 2 mA to 10 mA

Bias Output Voltage
12 VDC

Grounding
Case grounded

Sensing Element Design
PZT ceramic / shear

Case Material
316L stainless steel

Mounting
10-32 captive socket head screw, 2-pole rare earth magnet (48 lb pull strength)

Output Connector
4-Pin, M12

Mating Connector
M12 - F4D

Non-volatile Memory
TEDS 1451.4 compatible

Vibration Limit
500 g peak

Shock Limit
5000 g peak

Electromagnetic Sensitivity, Equivalent g
100 μg/gauss

Sealing
Hermetic

Temperature Range
-50°C to 120°C (-58°F to 248°F) ±7%

Warranty
One-year

Tachometer Specifications

Dimensions (D x W)
2.86 x 12.19 cm (1.125 x 4.80 in)

Weight
96 g (3.4 oz) with cable

Power
Powered by 810 Vibration Tester

Detection
Laser Diode Class 2

Range
6.0 to 99,999 rpm

Accuracy
6.0 to 5999.9 rpm > ±0.01% and ±1 digit
5999.9 to 99999 rpm > ±0.05% and ±1 digit

Resolution
0.1 rpm

Effective Range
1 cm to 100 cm (0.4 in to 39.27 in)

Response Time
1 second (> 60 rpm)

Controls
Measure on/off transparent button

Interface
6 Pin Mini DIN

Cable Length
50 cm (19.586 in)

Warranty
One-year

Tachometer Accessories
Reflective tape    1.5 x 52.5 cm (0.59 x 20.67 in)

In The Box :

Vibration Tester with diagnostic technology
Tri-axial accelerometer, magnet mount, mounting pad kit with adhesive, accelerometer quick-disconnect cable
Laser tachometer and storage pouch
Smart battery pack with cable and adapters
Shoulder strap and adjustable hand strap
Mini USB to USB cable
Getting Started Guide, illustrated quick reference guide, Users Manual CD-ROM,
Carrying case

Also you can check product : NEW Fluke 810 Vibration Tester

  • Availability: 16 In Stock
  • Model: Fluke 810
  • Brand: FLUKE

Write Review

Note: Do not use HTML in the text.