Bently Nevada
The SCOUT100EX Vibration Data Collector, Analyzer and Balancer is a portable hardware monitoring device that supports dual-channel vibration data collection, analysis, and balancing. Use the device to collect data from sensors on a route, for machine-side analysis and diagnosis, and on-site dynamic balance correction. The SCOUT100EX is ATEX Zone 2 and IECEx Zone 2 compliant and safe for hazardous areas. It is both light and rugged. The neck strap includes an integrated Sensor Keeper that restrains your sensor while you walk or climb to reach other machines.
The SCOUT100EX Vibration Data Collector, Analyzer and Balancer is a portable hardware monitoring device that supports dual-channel vibration data collection, analysis, and balancing. Use the device to collect data from sensors on a route, for machine-side analysis and diagnosis, and on-site dynamic balance correction.
The SCOUT100EX is ATEX Zone 2 and IECEx Zone 2 compliant and safe for hazardous areas. It is both light and rugged. The neck strap includes an integrated Sensor Keeper that restrains your sensor while you walk or climb to reach other machines.
Recording of high-resolution spectra and recording of very long time signals four-channel measurement, as well as time signal and spectrum analysis versatile frequency ranges and spectrum resolutions measurement of time signal and demodulation (Bearing Impact Demodulation) measurement of effective vibration value, speed and phase angle one- and two-plane on-site dynamic rotating machine balancing during operation, non-destructive electric motor analysis by phase-by-phase supply current spectrum analysis.
The Commtest vb7 and Scout100-Ex Two-Channel Vibration Analyzers are suitable for every level of vibration analyst - From novice to expert . These instruments offer the power and convenience of dual-channel measurement and dual-plane balancing. Their balancing functions enable quick diagnosis and correction of dynamic unbalance. The SCOUT100-Ex and vb7 instruments combine accuracy, intuitive operation, ease of use, and outstanding storage capacity to ensure a premium return on investment. The SCOUT100-Ex is certified for an ATEX Zone 2 hazardous rating, whereas the vb7 is rated for CSA Class 1, Division 2.
USED Bently Nevada Scout100-Ex Vibration Data Collector, Analyzer and Balancer (Scout100-Ex)
The SCOUT100EX Vibration Data Collector, Analyzer and Balancer is a portable hardware monitoring device that supports dual-channel vibration data collection, analysis, and balancing. Use the device to collect data from sensors on a route, for machine-side analysis and diagnosis, and on-site dynamic balance correction.
The SCOUT100EX is ATEX Zone 2 and IECEx Zone 2 compliant and safe for hazardous areas. It is both light and rugged. The neck strap includes an integrated Sensor Keeper that restrains your sensor while you walk or climb to reach other machines.
The SCOUT100EX Vibration Data Collector, Analyzer and Balancer is a portable hardware monitoring device that supports dual-channel vibration data collection, analysis, and balancing. Use the device to collect data from sensors on a route, for machine-side analysis and diagnosis, and on-site dynamic balance correction.
The SCOUT100EX is ATEX Zone 2 and IECEx Zone 2 compliant and safe for hazardous areas. It is both light and rugged. The neck strap includes an integrated Sensor Keeper that restrains your sensor while you walk or climb to reach other machines.
The SCOUT100EX is ATEX Zone 2 and IECEx Zone 2 compliant and safe for hazardous areas. It is both light and rugged. The neck strap includes an integrated Sensor Keeper that restrains your sensor while you walk or climb to reach other machines.
The device includes a complete suite of advanced recording and analysis capabilities, including 6Pack recordings, coastdown and long time waveform.
The SCOUT100EX offers plenty of storage and long battery life. The device comes with a five year warranty. It works with System 1 software.
The SCOUT100EX Vibration Data Collector, Analyzer and Balancer offers the following features:
- Up to two-channel, simultaneous on-route recordings
- Unique 6Pack recording system
- DC-coupled sensor support
- One GB memory plus virtually unlimited spectra and waveform storage
- Ten hours of battery life
- 6,400 lines FFT resolution
- 40 kHz Fmax
- Wide measurement range — 1,000 g, 25,000mm/s, 2,500mm
- Two-plane balancing
- Laser speed sensor for automatic capture of machine running speed
- Keyphasor tach mode
- Dynamic range ≥ 95 dB
- USB host port for data transfer to external USB memory
- Excellent ergonomics for walk-around data collection
- High contrast, backlit and direct-sunlight readable LCD
- True left and right-handed operation
- Sensor cable self-test feature
- Lightweight, rugged IP65 rated case
- Five-year warranty on the instrument hardware
- ATEX and IECEx Zone 2 hazardous location certification
- Field-upgradable Proflash system and free firmware updates for five years
Specifications
Sensors
Sensor input
Two Channels Simultaneous sampling
Compatible sensor types
Accelerometer, velocity,displacement, current
AC coupled range
16 V peak-peak
Allows for ± 8 V sensor output
swing (± 80 g)
DC coupled ranges
0 to 20 V
-10 to 10 V
-20 to 0 V
E.g. for reading prox-probe gap
Connectors
Safety feature: Break-free inline connector
Analog to digital conversion
24-bit ADC
Sensor excitation current
0 mA or 2.2 mA (configurable),
24 V maximum
2.2 mA required power for
IEPE/ICP-type accelerometer
Sensor detection
Warns if short circuit or not connected
Waveform Display
Number of samples
1024, 2048, 4096, 8192, 16,384
Time scale
10 ms to 256 seconds or orders based from 1 to 999 revs
Time synchronous averages
1, 2, 4, 8, 16, 32, 64, 128
Only available when tachometer is triggered
Long time waveform
25 Hz to 40 kHz
Fmax
20 kHz dual channel
Long time waveform duration
14.7 million samples (total over channels)
E.g. for Fmax 1 kHz
Fsample = 2.56 kHz and
Duration = 1.6 hrs
Tachometer
Sensor
Laser sensor with reflective tape Sensor triggers on beam reflection
Laser sensor range
10 cm to 2 m nominal
Range depends on size of reflective tape
Other sensor types supported
Contact, TTL Pulse, Keyphasor
Instrument has optically isolated input
Power supply to sensor
5 V, 50 mA
TTL pulse rating
3.5 V (4 mA) min
28 V (5 mA) max Off-state 0.8 V
Keyphasor threshold
7.7 ± 0.5 V , 13.2 ± 0.8 V , 18.5 ± 1 V , Nominally 8 V, 13 V, 18 V
Speed range
10 RPM to 300,000 RPM (0.2 Hz to 5 kHz)
Pulse width at least 0.1 ms
Accuracy
± 0.1 %
Output to drive strobe
Up to 140 Hz (8400 CPM) Typical Depends on strobe type Special cable required
Logging and Analysis
Output formats
LCD screen, Ascent, XML, System 1
Data storage
Dual 1 GB non-volatile flash memories, Database mirror copy on second flash memory
Data storage structure
Folders/machines/points/locations/routes
No limits are applied 50 character names
Max folder size
10,000 measurement locations
Parameter Indication
Maximum levels (peak)
> 1000 g (10,000 m/s2)
> 1000 in/sec (25,000 mm/s)
> 20 in (500 mm)
> 10,000 Amps
Effective limit is sensor sensitivity
and output voltage
Dynamic signal range
> 95 dB typical at 400 line resolution
Harmonic distortion
Less than -70 dB typical Other distortions and noise are lower
Units
g or m/s2 or adB, in/s or mm/s or vdB, mil or mm or µm amps
0-peak, peak-peak or RMS, Auto-scale by 1000x when required US and SI options for adB and vdB
Magnitude & cursors
Overall RMS value Waveform True pk-pk , Dual cursors Harmonics, Digital readouts on chart
Base accuracy
± 1% of readings
approximately 0.1 dB
For DC level — % of full scale
For AC signal — % of reading
High frequency attenuation
≤ 0.1 dB >100 Hz to 10 kHz
≤ 3 dB >10 kHz to 40 kHz
Attenuation tolerances are in addition to base accuracy.
AC coupling attenuation
≤ 0.1 dB 10 Hz to <100 Hz
≤ 3 dB 1 Hz to <10 Hz
Attenuation due to Integration
≤ 0.1 dB 1 Hz to <100 Hz
≤ 1.5 dB 0.2 Hz to <1 Hz
≤ 0.1 dB 10 Hz to <100 Hz
≤ 1.5 dB 1 Hz to <10 Hz
Low frequency mode:
When Coupling = DC and Fmax
≤ 100 Hz
Normal mode is applicable in all other cases. Values apply to single integration.
(Acceleration to velocity) Double the values for double integration (Acceleration to displacement)
Balancing
Planes
Up to 2 planes, 2 sensors
Speed range
30 to 60,000 RPM
Measurement type
Acceleration, velocity, displacement
Weight modes
Angle 0° to 360°, fixed position,
circumference arc
E.g. weights on fan blades, linear distance around circumference
Remove trial weights
Yes/No Automatic recalculation
Manual data entry
Yes Allows re-entry of previous balance jobs
Storage
Against machines in data structure,No limits applied
Mechanical
Size 9.9" W x 5.8" L x 2.4" H (252 x 148 x 60 mm)
Weight 2.7 lb (1.2 kg)
Including battery and strap
Spectrum Display
Fmax ranges
25, 50, 100, 125, 150, 200, 300,400, 500, 600, 800, 1000, 1200,
1600, 2000, 2500, 3000, 4000, 5000, 6000, 8000, 10,000,15,000, 20,000, 30,000, 40,000 Hz
Or equivalent CPM values, Or orders-based from 1X to 999X
Fmin possible range
0 to Fmax
Instrument zeroes all spectral lines below Fmin.
Resolution
400, 800, 1600, 3200, 6400
lines. 3200 lines max. for dual channel measurements
Frequency scale
Hz, CPM, Orders, Linear scale with zooming
Amplitude scale
Acceleration, velocity, displacement or current Linear or log scales, auto or manual scaling.
Window shapes Hanning Rectangular
Overlap
(0, 12.5, 25, 37.5, 50, 62.5, 75, 87.5) %
Depends on Fmax and number of lines
Number of averages
1, 2, 4, 8, 16, 32, 64, 128
Increases sampling time proportionally
Averaging types
Linear, exponential, peak hold, synchronous
Demodulation bandwidths
23 bandwidth options
From 125 Hz to 1250 Hz Up to 16 kHz to 20 kHz
6Pack
Up to 40 kHz & 3200 lines (1 channel)
Up to 20 kHz & 1600 lines (2 channels)
Spectrum and waveform for low-frequency,high-frequency demodulation
Order tracking
Up to 6 kHz Fmax, orders based Tachometer required Mounted on high-speed shaft
Order tracking - Distortion
Less than -65 dB
Within 50% to 200% speed variation during recording
Display and Communication
Display
Graphic Grayscale LCD , White LED Backlight
Resolution & size
480 x 320 (HVGA), 5.5” (140 mm) Readable in direct sunlight
Supported Languages
English, French, Spanish, Portuguese, Russian, Chinese
Communication with PC
US and Ethernet (optional USB dongle), Use PROFLASH to upgrade instrument firmware
USB host port
USB 2.0, supplying 5V, 250mA, Save folders to USB flash drive
Battery and Charger
Battery type
Custom Lithium Ion pack, 7.4 V, 5000 mAh
Operating time
10 hours Backlight on — 60 second timeout
Charger type
Internal charging, automatic control, External power pack 12 V DC, 3 A output
Charge rate
3 A nominal
3 hours for complete charge
Environmental Limits
Operating temperature
14 °F to 122 °F (-10 to 50 °C)
Storage temperature & humidity
-4 °F to 140 °F (-20 to 60 °C), 95% RH, Up to 95 F (35 C), 85% RH if
storage exceeds one month
Ruggedness
4’ (1.2 m) drop onto concrete,IP65
Procedure: 26 drops following
MIL-STD-810F-516.5-IV
Also you can check product : NEW Bently Nevada Scout100-Ex Vibration Data Collector, Analyzer and Balancer
The SCOUT100EX is ATEX Zone 2 and IECEx Zone 2 compliant and safe for hazardous areas. It is both light and rugged. The neck strap includes an integrated Sensor Keeper that restrains your sensor while you walk or climb to reach other machines.
The SCOUT100EX Vibration Data Collector, Analyzer and Balancer is a portable hardware monitoring device that supports dual-channel vibration data collection, analysis, and balancing. Use the device to collect data from sensors on a route, for machine-side analysis and diagnosis, and on-site dynamic balance correction.
The SCOUT100EX is ATEX Zone 2 and IECEx Zone 2 compliant and safe for hazardous areas. It is both light and rugged. The neck strap includes an integrated Sensor Keeper that restrains your sensor while you walk or climb to reach other machines.
The SCOUT100EX is ATEX Zone 2 and IECEx Zone 2 compliant and safe for hazardous areas. It is both light and rugged. The neck strap includes an integrated Sensor Keeper that restrains your sensor while you walk or climb to reach other machines.
The device includes a complete suite of advanced recording and analysis capabilities, including 6Pack recordings, coastdown and long time waveform.
The SCOUT100EX offers plenty of storage and long battery life. The device comes with a five year warranty. It works with System 1 software.
The SCOUT100EX Vibration Data Collector, Analyzer and Balancer offers the following features:
- Up to two-channel, simultaneous on-route recordings
- Unique 6Pack recording system
- DC-coupled sensor support
- One GB memory plus virtually unlimited spectra and waveform storage
- Ten hours of battery life
- 6,400 lines FFT resolution
- 40 kHz Fmax
- Wide measurement range — 1,000 g, 25,000mm/s, 2,500mm
- Two-plane balancing
- Laser speed sensor for automatic capture of machine running speed
- Keyphasor tach mode
- Dynamic range ≥ 95 dB
- USB host port for data transfer to external USB memory
- Excellent ergonomics for walk-around data collection
- High contrast, backlit and direct-sunlight readable LCD
- True left and right-handed operation
- Sensor cable self-test feature
- Lightweight, rugged IP65 rated case
- Five-year warranty on the instrument hardware
- ATEX and IECEx Zone 2 hazardous location certification
- Field-upgradable Proflash system and free firmware updates for five years
Specifications
Sensors
Sensor input
Two Channels Simultaneous sampling
Compatible sensor types
Accelerometer, velocity,displacement, current
AC coupled range
16 V peak-peak
Allows for ± 8 V sensor output
swing (± 80 g)
DC coupled ranges
0 to 20 V
-10 to 10 V
-20 to 0 V
E.g. for reading prox-probe gap
Connectors
Safety feature: Break-free inline connector
Analog to digital conversion
24-bit ADC
Sensor excitation current
0 mA or 2.2 mA (configurable),
24 V maximum
2.2 mA required power for
IEPE/ICP-type accelerometer
Sensor detection
Warns if short circuit or not connected
Waveform Display
Number of samples
1024, 2048, 4096, 8192, 16,384
Time scale
10 ms to 256 seconds or orders based from 1 to 999 revs
Time synchronous averages
1, 2, 4, 8, 16, 32, 64, 128
Only available when tachometer is triggered
Long time waveform
25 Hz to 40 kHz
Fmax
20 kHz dual channel
Long time waveform duration
14.7 million samples (total over channels)
E.g. for Fmax 1 kHz
Fsample = 2.56 kHz and
Duration = 1.6 hrs
Tachometer
Sensor
Laser sensor with reflective tape Sensor triggers on beam reflection
Laser sensor range
10 cm to 2 m nominal
Range depends on size of reflective tape
Other sensor types supported
Contact, TTL Pulse, Keyphasor
Instrument has optically isolated input
Power supply to sensor
5 V, 50 mA
TTL pulse rating
3.5 V (4 mA) min
28 V (5 mA) max Off-state 0.8 V
Keyphasor threshold
7.7 ± 0.5 V , 13.2 ± 0.8 V , 18.5 ± 1 V , Nominally 8 V, 13 V, 18 V
Speed range
10 RPM to 300,000 RPM (0.2 Hz to 5 kHz)
Pulse width at least 0.1 ms
Accuracy
± 0.1 %
Output to drive strobe
Up to 140 Hz (8400 CPM) Typical Depends on strobe type Special cable required
Logging and Analysis
Output formats
LCD screen, Ascent, XML, System 1
Data storage
Dual 1 GB non-volatile flash memories, Database mirror copy on second flash memory
Data storage structure
Folders/machines/points/locations/routes
No limits are applied 50 character names
Max folder size
10,000 measurement locations
Parameter Indication
Maximum levels (peak)
> 1000 g (10,000 m/s2)
> 1000 in/sec (25,000 mm/s)
> 20 in (500 mm)
> 10,000 Amps
Effective limit is sensor sensitivity
and output voltage
Dynamic signal range
> 95 dB typical at 400 line resolution
Harmonic distortion
Less than -70 dB typical Other distortions and noise are lower
Units
g or m/s2 or adB, in/s or mm/s or vdB, mil or mm or µm amps
0-peak, peak-peak or RMS, Auto-scale by 1000x when required US and SI options for adB and vdB
Magnitude & cursors
Overall RMS value Waveform True pk-pk , Dual cursors Harmonics, Digital readouts on chart
Base accuracy
± 1% of readings
approximately 0.1 dB
For DC level — % of full scale
For AC signal — % of reading
High frequency attenuation
≤ 0.1 dB >100 Hz to 10 kHz
≤ 3 dB >10 kHz to 40 kHz
Attenuation tolerances are in addition to base accuracy.
AC coupling attenuation
≤ 0.1 dB 10 Hz to <100 Hz
≤ 3 dB 1 Hz to <10 Hz
Attenuation due to Integration
≤ 0.1 dB 1 Hz to <100 Hz
≤ 1.5 dB 0.2 Hz to <1 Hz
≤ 0.1 dB 10 Hz to <100 Hz
≤ 1.5 dB 1 Hz to <10 Hz
Low frequency mode:
When Coupling = DC and Fmax
≤ 100 Hz
Normal mode is applicable in all other cases. Values apply to single integration.
(Acceleration to velocity) Double the values for double integration (Acceleration to displacement)
Balancing
Planes
Up to 2 planes, 2 sensors
Speed range
30 to 60,000 RPM
Measurement type
Acceleration, velocity, displacement
Weight modes
Angle 0° to 360°, fixed position,
circumference arc
E.g. weights on fan blades, linear distance around circumference
Remove trial weights
Yes/No Automatic recalculation
Manual data entry
Yes Allows re-entry of previous balance jobs
Storage
Against machines in data structure,No limits applied
Mechanical
Size 9.9" W x 5.8" L x 2.4" H (252 x 148 x 60 mm)
Weight 2.7 lb (1.2 kg)
Including battery and strap
Spectrum Display
Fmax ranges
25, 50, 100, 125, 150, 200, 300,400, 500, 600, 800, 1000, 1200,
1600, 2000, 2500, 3000, 4000, 5000, 6000, 8000, 10,000,15,000, 20,000, 30,000, 40,000 Hz
Or equivalent CPM values, Or orders-based from 1X to 999X
Fmin possible range
0 to Fmax
Instrument zeroes all spectral lines below Fmin.
Resolution
400, 800, 1600, 3200, 6400
lines. 3200 lines max. for dual channel measurements
Frequency scale
Hz, CPM, Orders, Linear scale with zooming
Amplitude scale
Acceleration, velocity, displacement or current Linear or log scales, auto or manual scaling.
Window shapes Hanning Rectangular
Overlap
(0, 12.5, 25, 37.5, 50, 62.5, 75, 87.5) %
Depends on Fmax and number of lines
Number of averages
1, 2, 4, 8, 16, 32, 64, 128
Increases sampling time proportionally
Averaging types
Linear, exponential, peak hold, synchronous
Demodulation bandwidths
23 bandwidth options
From 125 Hz to 1250 Hz Up to 16 kHz to 20 kHz
6Pack
Up to 40 kHz & 3200 lines (1 channel)
Up to 20 kHz & 1600 lines (2 channels)
Spectrum and waveform for low-frequency,high-frequency demodulation
Order tracking
Up to 6 kHz Fmax, orders based Tachometer required Mounted on high-speed shaft
Order tracking - Distortion
Less than -65 dB
Within 50% to 200% speed variation during recording
Display and Communication
Display
Graphic Grayscale LCD , White LED Backlight
Resolution & size
480 x 320 (HVGA), 5.5” (140 mm) Readable in direct sunlight
Supported Languages
English, French, Spanish, Portuguese, Russian, Chinese
Communication with PC
US and Ethernet (optional USB dongle), Use PROFLASH to upgrade instrument firmware
USB host port
USB 2.0, supplying 5V, 250mA, Save folders to USB flash drive
Battery and Charger
Battery type
Custom Lithium Ion pack, 7.4 V, 5000 mAh
Operating time
10 hours Backlight on — 60 second timeout
Charger type
Internal charging, automatic control, External power pack 12 V DC, 3 A output
Charge rate
3 A nominal
3 hours for complete charge
Environmental Limits
Operating temperature
14 °F to 122 °F (-10 to 50 °C)
Storage temperature & humidity
-4 °F to 140 °F (-20 to 60 °C), 95% RH, Up to 95 F (35 C), 85% RH if
storage exceeds one month
Ruggedness
4’ (1.2 m) drop onto concrete,IP65
Procedure: 26 drops following
MIL-STD-810F-516.5-IV
Also you can check product : NEW Bently Nevada Scout100-Ex Vibration Data Collector, Analyzer and Balancer
The SCOUT100EX Vibration Data Collector, Analyzer and Balancer is a portable hardware monitoring device that supports dual-channel vibration data collection, analysis, and balancing. Use the device to collect data from sensors on a route, for machine-side analysis and diagnosis, and on-site dynamic balance correction. The SCOUT100EX is ATEX Zone 2 and IECEx Zone 2 compliant and safe for hazardous areas. It is both light and rugged. The neck strap includes an integrated Sensor Keeper that restrains your sensor while you walk or climb to reach other machines.
NEW Bently Nevada Scout100-Ex Vibration Data Collector, Analyzer and Balancer (Scout100-Ex)
The SCOUT100EX Vibration Data Collector, Analyzer and Balancer is a portable hardware monitoring device that supports dual-channel vibration data collection, analysis, and balancing. Use the device to collect data from sensors on a route, for machine-side analysis and diagnosis, and on-site dynamic balance correction.
The SCOUT100EX is ATEX Zone 2 and IECEx Zone 2 compliant and safe for hazardous areas. It is both light and rugged. The neck strap includes an integrated Sensor Keeper that restrains your sensor while you walk or climb to reach other machines.
The SCOUT100EX is ATEX Zone 2 and IECEx Zone 2 compliant and safe for hazardous areas. It is both light and rugged. The neck strap includes an integrated Sensor Keeper that restrains your sensor while you walk or climb to reach other machines.
The device includes a complete suite of advanced recording and analysis capabilities, including 6Pack recordings, coastdown and long time waveform.
The SCOUT100EX offers plenty of storage and long battery life. The device comes with a five year warranty. It works with System 1 software.
The SCOUT100EX Vibration Data Collector, Analyzer and Balancer offers the following features:
- Up to two-channel, simultaneous on-route recordings
- Unique 6Pack recording system
- DC-coupled sensor support
- One GB memory plus virtually unlimited spectra and waveform storage
- Ten hours of battery life
- 6,400 lines FFT resolution
- 40 kHz Fmax
- Wide measurement range — 1,000 g, 25,000mm/s, 2,500mm
- Two-plane balancing
- Laser speed sensor for automatic capture of machine running speed
- Keyphasor tach mode
- Dynamic range ≥ 95 dB
- USB host port for data transfer to external USB memory
- Excellent ergonomics for walk-around data collection
- High contrast, backlit and direct-sunlight readable LCD
- True left and right-handed operation
- Sensor cable self-test feature
- Lightweight, rugged IP65 rated case
- Five-year warranty on the instrument hardware
- ATEX and IECEx Zone 2 hazardous location certification
- Field-upgradable Proflash system and free firmware updates for five years
Specifications
Sensors
Sensor input
Two Channels Simultaneous sampling
Compatible sensor types
Accelerometer, velocity,displacement, current
AC coupled range
16 V peak-peak
Allows for ± 8 V sensor output
swing (± 80 g)
DC coupled ranges
0 to 20 V
-10 to 10 V
-20 to 0 V
E.g. for reading prox-probe gap
Connectors
Safety feature: Break-free inline connector
Analog to digital conversion
24-bit ADC
Sensor excitation current
0 mA or 2.2 mA (configurable),
24 V maximum
2.2 mA required power for
IEPE/ICP-type accelerometer
Sensor detection
Warns if short circuit or not connected
Waveform Display
Number of samples
1024, 2048, 4096, 8192, 16,384
Time scale
10 ms to 256 seconds or orders based from 1 to 999 revs
Time synchronous averages
1, 2, 4, 8, 16, 32, 64, 128
Only available when tachometer is triggered
Long time waveform
25 Hz to 40 kHz
Fmax
20 kHz dual channel
Long time waveform duration
14.7 million samples (total over channels)
E.g. for Fmax 1 kHz
Fsample = 2.56 kHz and
Duration = 1.6 hrs
Tachometer
Sensor
Laser sensor with reflective tape Sensor triggers on beam reflection
Laser sensor range
10 cm to 2 m nominal
Range depends on size of reflective tape
Other sensor types supported
Contact, TTL Pulse, Keyphasor
Instrument has optically isolated input
Power supply to sensor
5 V, 50 mA
TTL pulse rating
3.5 V (4 mA) min
28 V (5 mA) max Off-state 0.8 V
Keyphasor threshold
7.7 ± 0.5 V , 13.2 ± 0.8 V , 18.5 ± 1 V , Nominally 8 V, 13 V, 18 V
Speed range
10 RPM to 300,000 RPM (0.2 Hz to 5 kHz)
Pulse width at least 0.1 ms
Accuracy
± 0.1 %
Output to drive strobe
Up to 140 Hz (8400 CPM) Typical Depends on strobe type Special cable required
Logging and Analysis
Output formats
LCD screen, Ascent, XML, System 1
Data storage
Dual 1 GB non-volatile flash memories, Database mirror copy on second flash memory
Data storage structure
Folders/machines/points/locations/routes
No limits are applied 50 character names
Max folder size
10,000 measurement locations
Parameter Indication
Maximum levels (peak)
> 1000 g (10,000 m/s2)
> 1000 in/sec (25,000 mm/s)
> 20 in (500 mm)
> 10,000 Amps
Effective limit is sensor sensitivity
and output voltage
Dynamic signal range
> 95 dB typical at 400 line resolution
Harmonic distortion
Less than -70 dB typical Other distortions and noise are lower
Units
g or m/s2 or adB, in/s or mm/s or vdB, mil or mm or µm amps
0-peak, peak-peak or RMS, Auto-scale by 1000x when required US and SI options for adB and vdB
Magnitude & cursors
Overall RMS value Waveform True pk-pk , Dual cursors Harmonics, Digital readouts on chart
Base accuracy
± 1% of readings
approximately 0.1 dB
For DC level — % of full scale
For AC signal — % of reading
High frequency attenuation
≤ 0.1 dB >100 Hz to 10 kHz
≤ 3 dB >10 kHz to 40 kHz
Attenuation tolerances are in addition to base accuracy.
AC coupling attenuation
≤ 0.1 dB 10 Hz to <100 Hz
≤ 3 dB 1 Hz to <10 Hz
Attenuation due to Integration
≤ 0.1 dB 1 Hz to <100 Hz
≤ 1.5 dB 0.2 Hz to <1 Hz
≤ 0.1 dB 10 Hz to <100 Hz
≤ 1.5 dB 1 Hz to <10 Hz
Low frequency mode:
When Coupling = DC and Fmax
≤ 100 Hz
Normal mode is applicable in all other cases. Values apply to single integration.
(Acceleration to velocity) Double the values for double integration (Acceleration to displacement)
Balancing
Planes
Up to 2 planes, 2 sensors
Speed range
30 to 60,000 RPM
Measurement type
Acceleration, velocity, displacement
Weight modes
Angle 0° to 360°, fixed position,
circumference arc
E.g. weights on fan blades, linear distance around circumference
Remove trial weights
Yes/No Automatic recalculation
Manual data entry
Yes Allows re-entry of previous balance jobs
Storage
Against machines in data structure,No limits applied
Mechanical
Size 9.9" W x 5.8" L x 2.4" H (252 x 148 x 60 mm)
Weight 2.7 lb (1.2 kg)
Including battery and strap
Spectrum Display
Fmax ranges
25, 50, 100, 125, 150, 200, 300,400, 500, 600, 800, 1000, 1200,
1600, 2000, 2500, 3000, 4000, 5000, 6000, 8000, 10,000,15,000, 20,000, 30,000, 40,000 Hz
Or equivalent CPM values, Or orders-based from 1X to 999X
Fmin possible range
0 to Fmax
Instrument zeroes all spectral lines below Fmin.
Resolution
400, 800, 1600, 3200, 6400
lines. 3200 lines max. for dual channel measurements
Frequency scale
Hz, CPM, Orders, Linear scale with zooming
Amplitude scale
Acceleration, velocity, displacement or current
Linear or log scales, auto or manual scaling
Window shapes
Hanning Rectangular
Overlap
(0, 12.5, 25, 37.5, 50, 62.5, 75, 87.5) %
Depends on Fmax and number of lines
Number of averages
1, 2, 4, 8, 16, 32, 64, 128
Increases sampling time proportionally
Averaging types
Linear, exponential, peak hold, synchronous
Demodulation bandwidths
23 bandwidth options
From 125 Hz to 1250 Hz Up to 16 kHz to 20 kHz
6Pack
Up to 40 kHz & 3200 lines (1 channel)
Up to 20 kHz & 1600 lines (2 channels)
Spectrum and waveform for low-frequency,high-frequency demodulation
Order tracking
Up to 6 kHz Fmax, orders based Tachometer required Mounted on high-speed shaft
Order tracking - Distortion
Less than -65 dB
Within 50% to 200% speed variation during recording
Display and Communication
Display
Graphic Grayscale LCD , White LED Backlight
Resolution & size
480 x 320 (HVGA), 5.5” (140 mm) Readable in direct sunlight
Supported Languages
English, French, Spanish, Portuguese, Russian, Chinese
Communication with PC
US and Ethernet (optional USB dongle), Use PROFLASH to upgrade instrument firmware
USB host port
USB 2.0, supplying 5V, 250mA, Save folders to USB flash drive
Battery and Charger
Battery type
Custom Lithium Ion pack, 7.4 V, 5000 mAh
Operating time
10 hours Backlight on — 60 second timeout
Charger type
Internal charging, automatic control, External power pack 12 V DC, 3 A output
Charge rate
3 A nominal
3 hours for complete charge
Environmental Limits
Operating temperature
14 °F to 122 °F (-10 to 50 °C)
Storage temperature & humidity
-4 °F to 140 °F (-20 to 60 °C), 95% RH, Up to 95 F (35 C), 85% RH if
storage exceeds one month
Ruggedness
4’ (1.2 m) drop onto concrete,IP65
Procedure: 26 drops following
MIL-STD-810F-516.5-IV
Also you can check product : USED Bently Nevada Scout100-Ex Vibration Data Collector, Analyzer and Balancer
The SCOUT100EX is ATEX Zone 2 and IECEx Zone 2 compliant and safe for hazardous areas. It is both light and rugged. The neck strap includes an integrated Sensor Keeper that restrains your sensor while you walk or climb to reach other machines.
The SCOUT100EX is ATEX Zone 2 and IECEx Zone 2 compliant and safe for hazardous areas. It is both light and rugged. The neck strap includes an integrated Sensor Keeper that restrains your sensor while you walk or climb to reach other machines.
The device includes a complete suite of advanced recording and analysis capabilities, including 6Pack recordings, coastdown and long time waveform.
The SCOUT100EX offers plenty of storage and long battery life. The device comes with a five year warranty. It works with System 1 software.
The SCOUT100EX Vibration Data Collector, Analyzer and Balancer offers the following features:
- Up to two-channel, simultaneous on-route recordings
- Unique 6Pack recording system
- DC-coupled sensor support
- One GB memory plus virtually unlimited spectra and waveform storage
- Ten hours of battery life
- 6,400 lines FFT resolution
- 40 kHz Fmax
- Wide measurement range — 1,000 g, 25,000mm/s, 2,500mm
- Two-plane balancing
- Laser speed sensor for automatic capture of machine running speed
- Keyphasor tach mode
- Dynamic range ≥ 95 dB
- USB host port for data transfer to external USB memory
- Excellent ergonomics for walk-around data collection
- High contrast, backlit and direct-sunlight readable LCD
- True left and right-handed operation
- Sensor cable self-test feature
- Lightweight, rugged IP65 rated case
- Five-year warranty on the instrument hardware
- ATEX and IECEx Zone 2 hazardous location certification
- Field-upgradable Proflash system and free firmware updates for five years
Specifications
Sensors
Sensor input
Two Channels Simultaneous sampling
Compatible sensor types
Accelerometer, velocity,displacement, current
AC coupled range
16 V peak-peak
Allows for ± 8 V sensor output
swing (± 80 g)
DC coupled ranges
0 to 20 V
-10 to 10 V
-20 to 0 V
E.g. for reading prox-probe gap
Connectors
Safety feature: Break-free inline connector
Analog to digital conversion
24-bit ADC
Sensor excitation current
0 mA or 2.2 mA (configurable),
24 V maximum
2.2 mA required power for
IEPE/ICP-type accelerometer
Sensor detection
Warns if short circuit or not connected
Waveform Display
Number of samples
1024, 2048, 4096, 8192, 16,384
Time scale
10 ms to 256 seconds or orders based from 1 to 999 revs
Time synchronous averages
1, 2, 4, 8, 16, 32, 64, 128
Only available when tachometer is triggered
Long time waveform
25 Hz to 40 kHz
Fmax
20 kHz dual channel
Long time waveform duration
14.7 million samples (total over channels)
E.g. for Fmax 1 kHz
Fsample = 2.56 kHz and
Duration = 1.6 hrs
Tachometer
Sensor
Laser sensor with reflective tape Sensor triggers on beam reflection
Laser sensor range
10 cm to 2 m nominal
Range depends on size of reflective tape
Other sensor types supported
Contact, TTL Pulse, Keyphasor
Instrument has optically isolated input
Power supply to sensor
5 V, 50 mA
TTL pulse rating
3.5 V (4 mA) min
28 V (5 mA) max Off-state 0.8 V
Keyphasor threshold
7.7 ± 0.5 V , 13.2 ± 0.8 V , 18.5 ± 1 V , Nominally 8 V, 13 V, 18 V
Speed range
10 RPM to 300,000 RPM (0.2 Hz to 5 kHz)
Pulse width at least 0.1 ms
Accuracy
± 0.1 %
Output to drive strobe
Up to 140 Hz (8400 CPM) Typical Depends on strobe type Special cable required
Logging and Analysis
Output formats
LCD screen, Ascent, XML, System 1
Data storage
Dual 1 GB non-volatile flash memories, Database mirror copy on second flash memory
Data storage structure
Folders/machines/points/locations/routes
No limits are applied 50 character names
Max folder size
10,000 measurement locations
Parameter Indication
Maximum levels (peak)
> 1000 g (10,000 m/s2)
> 1000 in/sec (25,000 mm/s)
> 20 in (500 mm)
> 10,000 Amps
Effective limit is sensor sensitivity
and output voltage
Dynamic signal range
> 95 dB typical at 400 line resolution
Harmonic distortion
Less than -70 dB typical Other distortions and noise are lower
Units
g or m/s2 or adB, in/s or mm/s or vdB, mil or mm or µm amps
0-peak, peak-peak or RMS, Auto-scale by 1000x when required US and SI options for adB and vdB
Magnitude & cursors
Overall RMS value Waveform True pk-pk , Dual cursors Harmonics, Digital readouts on chart
Base accuracy
± 1% of readings
approximately 0.1 dB
For DC level — % of full scale
For AC signal — % of reading
High frequency attenuation
≤ 0.1 dB >100 Hz to 10 kHz
≤ 3 dB >10 kHz to 40 kHz
Attenuation tolerances are in addition to base accuracy.
AC coupling attenuation
≤ 0.1 dB 10 Hz to <100 Hz
≤ 3 dB 1 Hz to <10 Hz
Attenuation due to Integration
≤ 0.1 dB 1 Hz to <100 Hz
≤ 1.5 dB 0.2 Hz to <1 Hz
≤ 0.1 dB 10 Hz to <100 Hz
≤ 1.5 dB 1 Hz to <10 Hz
Low frequency mode:
When Coupling = DC and Fmax
≤ 100 Hz
Normal mode is applicable in all other cases. Values apply to single integration.
(Acceleration to velocity) Double the values for double integration (Acceleration to displacement)
Balancing
Planes
Up to 2 planes, 2 sensors
Speed range
30 to 60,000 RPM
Measurement type
Acceleration, velocity, displacement
Weight modes
Angle 0° to 360°, fixed position,
circumference arc
E.g. weights on fan blades, linear distance around circumference
Remove trial weights
Yes/No Automatic recalculation
Manual data entry
Yes Allows re-entry of previous balance jobs
Storage
Against machines in data structure,No limits applied
Mechanical
Size 9.9" W x 5.8" L x 2.4" H (252 x 148 x 60 mm)
Weight 2.7 lb (1.2 kg)
Including battery and strap
Spectrum Display
Fmax ranges
25, 50, 100, 125, 150, 200, 300,400, 500, 600, 800, 1000, 1200,
1600, 2000, 2500, 3000, 4000, 5000, 6000, 8000, 10,000,15,000, 20,000, 30,000, 40,000 Hz
Or equivalent CPM values, Or orders-based from 1X to 999X
Fmin possible range
0 to Fmax
Instrument zeroes all spectral lines below Fmin.
Resolution
400, 800, 1600, 3200, 6400
lines. 3200 lines max. for dual channel measurements
Frequency scale
Hz, CPM, Orders, Linear scale with zooming
Amplitude scale
Acceleration, velocity, displacement or current
Linear or log scales, auto or manual scaling
Window shapes
Hanning Rectangular
Overlap
(0, 12.5, 25, 37.5, 50, 62.5, 75, 87.5) %
Depends on Fmax and number of lines
Number of averages
1, 2, 4, 8, 16, 32, 64, 128
Increases sampling time proportionally
Averaging types
Linear, exponential, peak hold, synchronous
Demodulation bandwidths
23 bandwidth options
From 125 Hz to 1250 Hz Up to 16 kHz to 20 kHz
6Pack
Up to 40 kHz & 3200 lines (1 channel)
Up to 20 kHz & 1600 lines (2 channels)
Spectrum and waveform for low-frequency,high-frequency demodulation
Order tracking
Up to 6 kHz Fmax, orders based Tachometer required Mounted on high-speed shaft
Order tracking - Distortion
Less than -65 dB
Within 50% to 200% speed variation during recording
Display and Communication
Display
Graphic Grayscale LCD , White LED Backlight
Resolution & size
480 x 320 (HVGA), 5.5” (140 mm) Readable in direct sunlight
Supported Languages
English, French, Spanish, Portuguese, Russian, Chinese
Communication with PC
US and Ethernet (optional USB dongle), Use PROFLASH to upgrade instrument firmware
USB host port
USB 2.0, supplying 5V, 250mA, Save folders to USB flash drive
Battery and Charger
Battery type
Custom Lithium Ion pack, 7.4 V, 5000 mAh
Operating time
10 hours Backlight on — 60 second timeout
Charger type
Internal charging, automatic control, External power pack 12 V DC, 3 A output
Charge rate
3 A nominal
3 hours for complete charge
Environmental Limits
Operating temperature
14 °F to 122 °F (-10 to 50 °C)
Storage temperature & humidity
-4 °F to 140 °F (-20 to 60 °C), 95% RH, Up to 95 F (35 C), 85% RH if
storage exceeds one month
Ruggedness
4’ (1.2 m) drop onto concrete,IP65
Procedure: 26 drops following
MIL-STD-810F-516.5-IV
Also you can check product : USED Bently Nevada Scout100-Ex Vibration Data Collector, Analyzer and Balancer
The SCOUT100EX Vibration Data Collector, Analyzer and Balancer is a portable hardware monitoring device that supports dual-channel vibration data collection, analysis, and balancing. Use the device to collect data from sensors on a route, for machine-side analysis and diagnosis, and on-site dynamic balance correction.
The SCOUT100EX is ATEX Zone 2 and IECEx Zone 2 compliant and safe for hazardous areas. It is both light and rugged. The neck strap includes an integrated Sensor Keeper that restrains your sensor while you walk or climb to reach other machines.
USED Bently Nevada Commtest VB8 Vibration Analysis System (Commtest VB8)
The Bently Nevada Commtest VB8 Four Channel Vibration Analysis System is a uniquely sophisticated and feature-packed instrument that remains intuitive in operation and flexible enough to suit every level of vibration analysis, from novice through to expert. The Ascent® software included contains the collective experience of over 25 years of expert in-depth machine fault analysis.
FEATURES :
Fully automated measurement parameter and alarm setups based on The Proven Method from Technical Associates
ISO 2372 and 10816 standards
4 channel simultaneous recordings
Triax-enabled
12 800 lines FFT resolution
Support for 80 kHz Fmax
1GB memory – Virtually unlimited spectra storage
Modal Impact Testing & Cross Channel Spectrum (ODS)
Ability to export data in Universal File Format (UFF) for additional analysis in ODS software such as Vibrant Technology ME'scope
Large, high resolution (HVGA) backlit LCD
Support for acceleration, velocity, displacement, DC-coupled, current and voltage output sensors
Simultaneous acquisition – 2 plane balancing with up to 4 sensors
Unique Commtest 6Pack™ recording system
Numeric parameter input via keypad with Ascent® trend and alarm capability
Cable Test mode
Upgradable Proflash system
Includes:
COMM-VB8-CASE01 | Soft carry Case with shoulder strap
GENE-USB-72 | USB Cable Type A, to Type B 72"
COMM-VB8-CHARGER01 | DC Car Charger/ Adapter
COMM-CBCC0027 | BNC adapter cable
COMM-MAGF0104 | Accelometer Magnetic Base, Female
COMM-T296 | Triple BNC to lemo Cable
COMM-VB8-CHARGER02 | Power Supply 12V---3000mA with power cord
COMM-MVBX0250 | vbSeries Instrument Reference Guide
COMM-VB8-MAN01 | Quick Start Guide
COMM-780A-D2-NR | Accelerometer
COMM-VB*-CD01 | Implementation Success Training CD
COMM-NSSK0275 | Neck Strap with Sensor Keeper
COMM-VB8-COIL-CBL01 | Accelorometer Coiled Cable
COMM-LASA0315 | Laser tachometer
COMM-L188 | Tachometer Extension Cable, 5 meter
COMM-CB5G0024 | BNC Extension Cable, 5 meter (green)
COMM-CB5R0025 | BNC Extension Cable, 5 meter (red)
COMM-VB-CASE02 | Accessory Bag
COMM-VB8-MBS01 | Magnetic Base with Adjustable Stand
DELL-LATITUDE-D630 | DELL Latitude D630 Intel Core 2 Duo 2.20GHz 2GB Memory 80GB HDD 14.1 Windows 7 Professional
DELL-AA22850 | 65W AC/DC Adapter 19.5V 3.34A Output w/F2951 Power Cord
COMM-VB-R-TAPE01 | Reflective Tape
COMM-VB*-CD02 | Ascent Reference Guide CD
COMM-BATT0206 | Battery Pack (installed)
Also you can check product : USED Bently Nevada Scout100-Ex Vibration Data Collector, Analyzer and Balancer
FEATURES :
Fully automated measurement parameter and alarm setups based on The Proven Method from Technical Associates
ISO 2372 and 10816 standards
4 channel simultaneous recordings
Triax-enabled
12 800 lines FFT resolution
Support for 80 kHz Fmax
1GB memory – Virtually unlimited spectra storage
Modal Impact Testing & Cross Channel Spectrum (ODS)
Ability to export data in Universal File Format (UFF) for additional analysis in ODS software such as Vibrant Technology ME'scope
Large, high resolution (HVGA) backlit LCD
Support for acceleration, velocity, displacement, DC-coupled, current and voltage output sensors
Simultaneous acquisition – 2 plane balancing with up to 4 sensors
Unique Commtest 6Pack™ recording system
Numeric parameter input via keypad with Ascent® trend and alarm capability
Cable Test mode
Upgradable Proflash system
Includes:
COMM-VB8-CASE01 | Soft carry Case with shoulder strap
GENE-USB-72 | USB Cable Type A, to Type B 72"
COMM-VB8-CHARGER01 | DC Car Charger/ Adapter
COMM-CBCC0027 | BNC adapter cable
COMM-MAGF0104 | Accelometer Magnetic Base, Female
COMM-T296 | Triple BNC to lemo Cable
COMM-VB8-CHARGER02 | Power Supply 12V---3000mA with power cord
COMM-MVBX0250 | vbSeries Instrument Reference Guide
COMM-VB8-MAN01 | Quick Start Guide
COMM-780A-D2-NR | Accelerometer
COMM-VB*-CD01 | Implementation Success Training CD
COMM-NSSK0275 | Neck Strap with Sensor Keeper
COMM-VB8-COIL-CBL01 | Accelorometer Coiled Cable
COMM-LASA0315 | Laser tachometer
COMM-L188 | Tachometer Extension Cable, 5 meter
COMM-CB5G0024 | BNC Extension Cable, 5 meter (green)
COMM-CB5R0025 | BNC Extension Cable, 5 meter (red)
COMM-VB-CASE02 | Accessory Bag
COMM-VB8-MBS01 | Magnetic Base with Adjustable Stand
DELL-LATITUDE-D630 | DELL Latitude D630 Intel Core 2 Duo 2.20GHz 2GB Memory 80GB HDD 14.1 Windows 7 Professional
DELL-AA22850 | 65W AC/DC Adapter 19.5V 3.34A Output w/F2951 Power Cord
COMM-VB-R-TAPE01 | Reflective Tape
COMM-VB*-CD02 | Ascent Reference Guide CD
COMM-BATT0206 | Battery Pack (installed)
Also you can check product : USED Bently Nevada Scout100-Ex Vibration Data Collector, Analyzer and Balancer
Recording of high-resolution spectra and recording of very long time signals four-channel measurement, as well as time signal and spectrum analysis versatile frequency ranges and spectrum resolutions measurement of time signal and demodulation (Bearing Impact Demodulation) measurement of effective vibration value, speed and phase angle one- and two-plane on-site dynamic rotating machine balancing during operation, non-destructive electric motor analysis by phase-by-phase supply current spectrum analysis.
USED Bently Nevada Commtest VB7 2 Channel Vibration Analyzer (Commtest VB7 2)
The Commtest VB7 Dual Channel Vibration Analyzer offers the power and convenience of dual-channel measurement and dual-plane balancing. Its balancing functions enable quick diagnosis and correction of dynamic unbalance, the most common form of unbalance. The VB7 Vibration Analyzer's combination of accuracy, intuitive operation, ease of use, and outstanding storage capacity ensures the instrument delivers a premium return on investment. The Commtest VB7 includes the powerful, award-winning Ascent software.
SPECS :
Sensor input
2 channels
Compatible sensor types
Accelerometer, velocity, displacement, current
AC coupled range
16 V peak-peak
Allows for ± 8 V sensor output swing (± 80 g)
DC coupled ranges
0 V to 20 V, -10 V to 10 V, -20 V to 0 V
Analog to digital conversion
24-bit ADC
Sensor excitation current
0 mA or 2.2 mA (configurable), 24 V maximum
Laser sensor range
10 cm to 2 m nominal
Power supply to sensor
5 V, 50 mA
TTL pulse rating
3.5 V (4 mA) min, 28 V (5 mA) max, off-state 0.8 V
Speed range
10 to 300 000 RPM (0.2 to 5 kHz)
Output to drive strobe
Up to 140 Hz (8400 CPM)
Demodulation bandwidths
23 bandwidth options
From 125 Hz to 1250 Hz up to 16 kHz to 20 kHz
Long time waveform Fmax
25 Hz to 40 kHz
Dimensions (W x L x H)
9.9” x 5.8” x 2.4” (252 x 148 x 60) mm
Weight
2.7 lb. (1.2 kg)
Operating temperature
14°F to 122°F (-10°C to 50°C)
Includes :
COMM-CBCC0027 | BNC adapter cable
COMM-CBVB0032 | Carry Case
GENE-12V-3.0A | Power supply
GENE-PC-10A/125V | Power Cord
GENE-CAR-ADAPT01 | Car Charger for cigarette lighter
GENE-USB | USB Cable, Type A to Type B, 6'
COMM-NSSK0275 | Neck Strap with Sensor Keeper
COMM-BATT0206 | Battery Pack (installed)
COMM-VB7-COIL-CBL01 | Accelometer Coiled Cable
COMM-MVBX0250 | vbSeries Instrument Reference Guide
COMM-VB7-QSG01 | Quick Start Guide
COMM-VB*-CD01 | Implementation Success Training CD
WILC-780A-IS-NR | Accelerometer 5% tolerance and a broad 3dB frequency response from 0.4 Hz to 14 kHz
COMM-VB7-MBS01 | Magnetic Base with Adjustable Stand
COMM-L766 | Tachometer Extension Cable, 5 meter
COMM-CB5R0025 | BNC Extension Cable, 5 meter (red)
COMM-VB-CASE02 | Accessory Bag
COMM-LASA0315 | Laser tachometer
COMM-CB5G0024 | BNC Extension Cable, 5 meter (green)
DELL-LATITUDE-D620 | 2GB RAM, RS232 Interface, Windows XP Pro Laptop Computer
DELL-AA22850 | 65W AC/DC Adapter 19.5V 3.34A Output w/F2951 Power Cord
COMM-VB-R-TAPE01 | Reflective Tape
COMM-VB*-CD02 | Ascent Reference Guide CD
COMM-MAGM0064 | Accelometer Magnetic Base, Male
Also you can check product : USED Bently Nevada Commtest VB8 Vibration Analysis System
SPECS :
Sensor input
2 channels
Compatible sensor types
Accelerometer, velocity, displacement, current
AC coupled range
16 V peak-peak
Allows for ± 8 V sensor output swing (± 80 g)
DC coupled ranges
0 V to 20 V, -10 V to 10 V, -20 V to 0 V
Analog to digital conversion
24-bit ADC
Sensor excitation current
0 mA or 2.2 mA (configurable), 24 V maximum
Laser sensor range
10 cm to 2 m nominal
Power supply to sensor
5 V, 50 mA
TTL pulse rating
3.5 V (4 mA) min, 28 V (5 mA) max, off-state 0.8 V
Speed range
10 to 300 000 RPM (0.2 to 5 kHz)
Output to drive strobe
Up to 140 Hz (8400 CPM)
Demodulation bandwidths
23 bandwidth options
From 125 Hz to 1250 Hz up to 16 kHz to 20 kHz
Long time waveform Fmax
25 Hz to 40 kHz
Dimensions (W x L x H)
9.9” x 5.8” x 2.4” (252 x 148 x 60) mm
Weight
2.7 lb. (1.2 kg)
Operating temperature
14°F to 122°F (-10°C to 50°C)
Includes :
COMM-CBCC0027 | BNC adapter cable
COMM-CBVB0032 | Carry Case
GENE-12V-3.0A | Power supply
GENE-PC-10A/125V | Power Cord
GENE-CAR-ADAPT01 | Car Charger for cigarette lighter
GENE-USB | USB Cable, Type A to Type B, 6'
COMM-NSSK0275 | Neck Strap with Sensor Keeper
COMM-BATT0206 | Battery Pack (installed)
COMM-VB7-COIL-CBL01 | Accelometer Coiled Cable
COMM-MVBX0250 | vbSeries Instrument Reference Guide
COMM-VB7-QSG01 | Quick Start Guide
COMM-VB*-CD01 | Implementation Success Training CD
WILC-780A-IS-NR | Accelerometer 5% tolerance and a broad 3dB frequency response from 0.4 Hz to 14 kHz
COMM-VB7-MBS01 | Magnetic Base with Adjustable Stand
COMM-L766 | Tachometer Extension Cable, 5 meter
COMM-CB5R0025 | BNC Extension Cable, 5 meter (red)
COMM-VB-CASE02 | Accessory Bag
COMM-LASA0315 | Laser tachometer
COMM-CB5G0024 | BNC Extension Cable, 5 meter (green)
DELL-LATITUDE-D620 | 2GB RAM, RS232 Interface, Windows XP Pro Laptop Computer
DELL-AA22850 | 65W AC/DC Adapter 19.5V 3.34A Output w/F2951 Power Cord
COMM-VB-R-TAPE01 | Reflective Tape
COMM-VB*-CD02 | Ascent Reference Guide CD
COMM-MAGM0064 | Accelometer Magnetic Base, Male
Also you can check product : USED Bently Nevada Commtest VB8 Vibration Analysis System
The Commtest vb7 and Scout100-Ex Two-Channel Vibration Analyzers are suitable for every level of vibration analyst - From novice to expert . These instruments offer the power and convenience of dual-channel measurement and dual-plane balancing. Their balancing functions enable quick diagnosis and correction of dynamic unbalance. The SCOUT100-Ex and vb7 instruments combine accuracy, intuitive operation, ease of use, and outstanding storage capacity to ensure a premium return on investment. The SCOUT100-Ex is certified for an ATEX Zone 2 hazardous rating, whereas the vb7 is rated for CSA Class 1, Division 2.
- 1