NEW Bently Nevada Scout100-Ex Vibration Data Collector, Analyzer and Balancer

The SCOUT100EX Vibration Data Collector, Analyzer and Balancer is a portable hardware monitoring device that supports dual-channel vibration data collection, analysis, and balancing. Use the device to collect data from sensors on a route, for machine-side analysis and diagnosis, and on-site dynamic balance correction. The SCOUT100EX is ATEX Zone 2 and IECEx Zone 2 compliant and safe for hazardous areas. It is both light and rugged. The neck strap includes an integrated Sensor Keeper that restrains your sensor while you walk or climb to reach other machines.
£3,791.97
Qty:
The SCOUT100EX Vibration Data Collector, Analyzer and Balancer is a portable hardware monitoring device that supports dual-channel vibration data collection, analysis, and balancing. Use the device to collect data from sensors on a route, for machine-side analysis and diagnosis, and on-site dynamic balance correction.

The SCOUT100EX is ATEX Zone 2 and IECEx Zone 2 compliant and safe for hazardous areas. It is both light and rugged. The neck strap includes an integrated Sensor Keeper that restrains your sensor while you walk or climb to reach other machines.

The SCOUT100EX is ATEX Zone 2 and IECEx Zone 2 compliant and safe for hazardous areas. It is both light and rugged. The neck strap includes an integrated Sensor Keeper that restrains your sensor while you walk or climb to reach other machines.

The device includes a complete suite of advanced recording and analysis capabilities, including 6Pack recordings, coastdown and long time waveform. 

The SCOUT100EX offers plenty of storage and long battery life. The device comes with a five year warranty. It works with System 1 software.

The SCOUT100EX Vibration Data Collector, Analyzer and Balancer offers the following features:

- Up to two-channel, simultaneous on-route recordings
- Unique 6Pack recording system
- DC-coupled sensor support
- One GB memory plus virtually unlimited spectra and waveform storage
- Ten hours of battery life
- 6,400 lines FFT resolution
- 40 kHz Fmax
- Wide measurement range — 1,000 g, 25,000mm/s, 2,500mm
- Two-plane balancing
- Laser speed sensor for automatic capture of machine running speed
- Keyphasor tach mode
- Dynamic range ≥ 95 dB
- USB host port for data transfer to external USB memory
- Excellent ergonomics for walk-around data collection
- High contrast, backlit and direct-sunlight readable LCD
- True left and right-handed operation
- Sensor cable self-test feature
- Lightweight, rugged IP65 rated case
- Five-year warranty on the instrument hardware
- ATEX and IECEx Zone 2 hazardous location certification
- Field-upgradable Proflash system and free firmware updates for five years

Specifications

Sensors

Sensor input
Two Channels Simultaneous sampling

Compatible sensor types
Accelerometer, velocity,displacement, current

AC coupled range
16 V peak-peak
Allows for ± 8 V sensor output
swing (± 80 g)

DC coupled ranges
0 to 20 V
-10 to 10 V
-20 to 0 V
E.g. for reading prox-probe gap

Connectors 
Safety feature: Break-free inline connector

Analog to digital conversion
24-bit ADC

Sensor excitation current
0 mA or 2.2 mA (configurable),
24 V maximum
2.2 mA required power for
IEPE/ICP-type accelerometer

Sensor detection
Warns if short circuit or not connected

Waveform Display

Number of samples
1024, 2048, 4096, 8192, 16,384

Time scale
10 ms to 256 seconds or orders based from 1 to 999 revs

Time synchronous averages
1, 2, 4, 8, 16, 32, 64, 128
Only available when tachometer is triggered

Long time waveform
25 Hz to 40 kHz

Fmax
20 kHz dual channel

Long time waveform duration
14.7 million samples (total over channels)
E.g. for Fmax 1 kHz
Fsample = 2.56 kHz and
Duration = 1.6 hrs

Tachometer

Sensor
Laser sensor with reflective tape Sensor triggers on beam reflection

Laser sensor range
10 cm to 2 m nominal
Range depends on size of reflective tape

Other sensor types supported
Contact, TTL Pulse, Keyphasor
Instrument has optically isolated input

Power supply to sensor
5 V, 50 mA

TTL pulse rating
3.5 V (4 mA) min
28 V (5 mA) max Off-state 0.8 V

Keyphasor threshold
7.7 ± 0.5 V , 13.2 ± 0.8 V , 18.5 ± 1 V , Nominally 8 V, 13 V, 18 V

Speed range
10 RPM to 300,000 RPM (0.2 Hz to 5 kHz)
Pulse width at least 0.1 ms

Accuracy 
± 0.1 %

Output to drive strobe
Up to 140 Hz (8400 CPM) Typical Depends on strobe type Special cable required

Logging and Analysis

Output formats
LCD screen, Ascent, XML, System 1

Data storage
Dual 1 GB non-volatile flash memories, Database mirror copy on second flash memory

Data storage structure
Folders/machines/points/locations/routes
No limits are applied 50 character names

Max folder size
10,000 measurement locations

Parameter Indication

Maximum levels (peak)
> 1000 g (10,000 m/s2)
> 1000 in/sec (25,000 mm/s)
> 20 in (500 mm)
> 10,000 Amps
Effective limit is sensor sensitivity
and output voltage

Dynamic signal range
> 95 dB typical at 400 line resolution

Harmonic distortion
Less than -70 dB typical Other distortions and noise are lower

Units
g or m/s2 or adB, in/s or mm/s or vdB, mil or mm or µm amps
0-peak, peak-peak or RMS, Auto-scale by 1000x when required US and SI options for adB and vdB

Magnitude & cursors
Overall RMS value Waveform True pk-pk , Dual cursors Harmonics, Digital readouts on chart

Base accuracy
± 1% of readings
approximately 0.1 dB
For DC level — % of full scale
For AC signal — % of reading

High frequency attenuation
≤ 0.1 dB >100 Hz to 10 kHz
≤ 3 dB >10 kHz to 40 kHz
Attenuation tolerances are in addition to base accuracy.

AC coupling attenuation
≤ 0.1 dB 10 Hz to <100 Hz
≤ 3 dB 1 Hz to <10 Hz

Attenuation due to Integration
≤ 0.1 dB 1 Hz to <100 Hz
≤ 1.5 dB 0.2 Hz to <1 Hz
≤ 0.1 dB 10 Hz to <100 Hz
≤ 1.5 dB 1 Hz to <10 Hz
Low frequency mode:
When Coupling = DC and Fmax
≤ 100 Hz
Normal mode is applicable in all other cases. Values apply to single integration.
(Acceleration to velocity) Double the values for double integration (Acceleration to displacement)

Balancing

Planes
Up to 2 planes, 2 sensors

Speed range
30 to 60,000 RPM
Measurement type
Acceleration, velocity, displacement

Weight modes
Angle 0° to 360°, fixed position,
circumference arc
E.g. weights on fan blades, linear distance around circumference

Remove trial weights
Yes/No Automatic recalculation

Manual data entry
Yes Allows re-entry of previous balance jobs

Storage
Against machines in data structure,No limits applied

Mechanical

Size 9.9" W x 5.8" L x 2.4" H (252 x 148 x 60 mm)
Weight 2.7 lb (1.2 kg)
Including battery and strap

Spectrum Display

Fmax ranges
25, 50, 100, 125, 150, 200, 300,400, 500, 600, 800, 1000, 1200,
1600, 2000, 2500, 3000, 4000, 5000, 6000, 8000, 10,000,15,000, 20,000, 30,000, 40,000 Hz
Or equivalent CPM values, Or orders-based from 1X to 999X

Fmin possible range
0 to Fmax
Instrument zeroes all spectral lines below Fmin.

Resolution
400, 800, 1600, 3200, 6400
lines. 3200 lines max. for dual channel measurements

Frequency scale
Hz, CPM, Orders, Linear scale with zooming

Amplitude scale
Acceleration, velocity, displacement or current
Linear or log scales, auto or manual scaling

Window shapes
Hanning Rectangular

Overlap
(0, 12.5, 25, 37.5, 50, 62.5, 75, 87.5) %
Depends on Fmax and number of lines

Number of averages
1, 2, 4, 8, 16, 32, 64, 128
Increases sampling time proportionally

Averaging types
Linear, exponential, peak hold, synchronous

Demodulation bandwidths
23 bandwidth options
From 125 Hz to 1250 Hz Up to 16 kHz to 20 kHz

6Pack
Up to 40 kHz & 3200 lines (1 channel)
Up to 20 kHz & 1600 lines (2 channels)
Spectrum and waveform for low-frequency,high-frequency demodulation

Order tracking
Up to 6 kHz Fmax, orders based Tachometer required Mounted on high-speed shaft

Order tracking - Distortion
Less than -65 dB
Within 50% to 200% speed variation during recording

Display and Communication

Display
Graphic Grayscale LCD , White LED Backlight

Resolution & size
480 x 320 (HVGA), 5.5” (140 mm) Readable in direct sunlight

Supported Languages
English, French, Spanish, Portuguese, Russian, Chinese

Communication with PC
US and Ethernet (optional USB dongle), Use PROFLASH to upgrade instrument firmware

USB host port
USB 2.0, supplying 5V, 250mA, Save folders to USB flash drive

Battery and Charger

Battery type
Custom Lithium Ion pack, 7.4 V, 5000 mAh

Operating time
10 hours Backlight on — 60 second timeout

Charger type
Internal charging, automatic control, External power pack 12 V DC, 3 A output

Charge rate
3 A nominal
3 hours for complete charge

Environmental Limits

Operating temperature
14 °F to 122 °F (-10 to 50 °C)

Storage temperature & humidity
-4 °F to 140 °F (-20 to 60 °C), 95% RH, Up to 95 F (35 C), 85% RH if
storage exceeds one month

Ruggedness
4’ (1.2 m) drop onto concrete,IP65
Procedure: 26 drops following
MIL-STD-810F-516.5-IV

Also you can check product : USED Bently Nevada Scout100-Ex Vibration Data Collector, Analyzer and Balancer

  • Availability: 24 In Stock
  • Model: Scout100-Ex
  • Brand: Bently Nevada

Write Review