NEW Olympus Epoch 650 Ultrasonic Flaw Detector

The EPOCH 650 is designed to meet the requirements of ISO 22232-1 and allows a full range of standard and optional flaw detection features. Multiple onboard reporting tools and a comprehensive data filing system enable you to easily collect and report high quality inspection data. The rugged, ergonomic design allows use in nearly any inspection environment, while the flexible PerfectSquare pulser and highest number of digital filters in its class can tackle nearly any application. The EPOCH 650 Digital Ultrasonic Flaw Detector combines Olympus’ industry leading conventional flaw detection capabilities with the efficiency of a highly portable, intuitive instrument.
£2,233.14
Qty:
EPOCH 650 Ultrasonic Flaw Detector

Economical Size, Quality Performance
The large, full VGA transflective display combined with our patented digital high dynamic range receiver provides a stable, striking A-scan representation in any lighting condition. The EPOCH 650 is designed to meet the requirements of ISO 22232-1 and allows a full range of standard and optional flaw detection features. Multiple onboard reporting tools and a comprehensive data filing system enable you to easily collect and report high quality inspection data. The rugged, ergonomic design allows use in nearly any inspection environment, while the flexible PerfectSquare pulser and highest number of digital filters in its class can tackle nearly any application.

The EPOCH 650 Digital Ultrasonic Flaw Detector combines Olympus’ industry leading conventional flaw detection capabilities with the efficiency of a highly portable, intuitive instrument. The EPOCH 650 flaw detector’s blend of efficient menus and direct access keys allows you to take advantage of the highest quality flaw detection platform with exceptional ease of use. 

Designed for All Inspection Environments

The EPOCH 650 is designed for use in nearly any inspection environment, from bench top testing in a laboratory to extreme outdoor and hazardous conditions. Designed for IP rating in either knob (IP66) or navigation pad (IP67) configurations, and tested to very high environmental and reliability standards, the EPOCH 650 allows users in any inspection environment to feel confident in both the performance and durability of the instrument.

Features

Designed to meet the requirements of ISO 22232-1
PerfectSquareTM tunable square wave pulser
Full screen A-scan mode
Digital high dynamic range receiver
Thirty digital filters for enhanced signal-to-noise ratio
2 kHz PRF for rapid scanning
Knob or navigation pad adjustment configurations
Large, full VGA sunlight readable display
15 hours of battery life
Standard dynamic DAC/TCG and onboard DGS/AVG
Multiple on-board report formats
MicroSD memory card for data transfers
Optional Corrosion Module software with Encoded B-scan
USB On-The-Go (OTG) for PC communication
Alarm and VGA outputs
Optional analog output

Simple and Comfortable Operation

The EPOCH 650 design is focused on providing a very high level of flaw detection with the simplicity of a basic instrument. The EPOCH 650 is designed to be ergonomic, intuitive, and practical for both experienced and novice ultrasonic inspectors.

Intuitive User Interface
The EPOCH 650 user interface is based on the industry leading EPOCH 600 flaw detector. The EPOCH 650 combines a simple menu structure for instrument settings, calibration and software feature adjustment, with the EPOCH brand’s hallmark direct-access key approach

for critical inspection functions such as gain and gate adjustment, screen freeze, and file save. Supported in multiple languages, the EPOCH 650 user interface is intuitive for any level of operator.

Vibrant VGA Display with Full Screen Mode
The EPOCH 650 features a full VGA (640 x 480 pixels) resolution display. The horizontal design of the EPOCH 650 optimizes the A-scan size and readability on this high quality display. Built with transflective technology, this VGA display provides excellent clarity in indoor, low lighting conditions using its powerful backlight, as well as in direct sunlight by using the ambient light as a pseudo-backlight.

The full screen mode feature enhances this vibrant display to provide the largest A-scan in an EPOCH series flaw detector!

Options for Comfortable Navigation
In order to accommodate different user needs and preferences, the EPOCH 650 is available in two hardware configurations:

Knob
The adjustment knob on the EPOCH 650 is used along with the CHECK and ESC keys to adjust parameter values in either coarse or fine increments. You have the ability to lock the knob to prevent accidental parameter value changes during an inspection. This configuration provides smooth value slewing for customers who prefer adjusting parameters using a knob. The knob configuration is designed to meet the requirements of IP66.

Navigation Pad
The EPOCH 650 navigation pad is a hallmark feature of the EPOCH flaw detectors. The up and down arrows on the navigation pad are used for coarse parameter adjustment, and the left and right arrows for fine adjustment. The navigation pad also contains additional functions and frequently used parameters such as gain, save, and the CHECK and ESC keys. The navigation pad configuration is designed to meet the requirements of IP67.

Portable, Rugged, and Ergonomic

Physical Features

The EPOCH 650 is a lightweight, portable flaw detector built to be rugged and flexible for nearly any inspection. Some key physical features include:

Large, full VGA resolution transflective display for vivid clarity in any indoor lighting and direct sunlight conditions
Rubber overmolded bumpers on all four corners for shock absorption and anti-marring considerations
Four-point harness connection for chest straps
“No tools” access to battery compartment and side I/O door
Continuous position stand with right angle crook for improved stability from 0 to 180 degrees
Gasketed side door for USB OTG connection and removable memory
Standard internal, rechargeable lithium-ion battery
Lightweight, ergonomic design for increased portability and ease of use

Standard Package

EPOCH 650 Digital ultrasonic flaw detector, AC or battery operation
Charger/AC adapter (100 VAC, 115 VAC, 230 VAC, 50 Hz or 60 Hz)
Rechargeable lithium-ion battery
Transport case
USB cable
Quick reference card
Comprehensive operation manual (CD) 

SPECS :

Instrument Inputs/Outputs

USB Ports
USB On-The-Go (OTG)

RS-232 Port
Yes

Video Output
VGA output standard

Analog Output
1 analog output (optional), Selectable 1 V/10 V Full Scale, 4mA max

Alarm Output
3 alarm outputs, 5 V TTL, 10 mA

Trigger I/O
Trigger input, 5V TTL;
Trigger output, 5V TTL, 10 mA max

Encoder Inputs
1-axis encoder line (quadrature - Corrosion Module mode only)

Environmental Ratings

IP Rating
Designed to meet the standards of the Ingress Protection (IP) rating number IP67 (navigation pad version) or IP66 (knob version) per IEC 60529-2004 (Degrees of Protection provided by enclosures – IP Code).
The product design was confirmed to meet the IP rating by means of Olympus internal design verification test process that occurs prior to the release of the product to production.

Explosive Atmosphere
Safe operation as defined by Class I, Division 2, Group D, as defined in the National Fire Protection Association Code (NFPA 70), Article 500, and tested using MIL-STD-810F, Method 511.4, Procedure I.

Shock Tested
MIL-STD-810F, Method 516.5 Procedure I, 6 cycles each axis, 15g, 11 ms half sine.

Vibration Tested
MIL-STD-810F, Method 514.5, Procedure I, Annex C, Figure 6, general exposure: 1 hour each axis

Operating Temperature
–10 °C to 50 °C (14 °F to 122 °F)

Battery Storage Temperature    
0 °C to 50 °C (32 °F to 122 °F)

General

Overall dimensions (W x H x D)
236 mm x 167 mm x 70 mm (9.3 in. x 6.57 in. x 2.76 in.)

Weight
1.6 kg (3.5 lb), including lithium-ion battery

Keypad
English, International, Japanese, Chinese

Languages
English, Spanish, French, German, Japanese, Chinese, Portuguese, Russian

Transducer connections
BNC or Number 1 LEMO

Data storage
100,000 IDs onboard, removable 2 GB MicroSD card (standard)

Battery type
Single lithium-ion rechargeable standard

Battery life
15 h to 16 h (lithium-ion)

Power requirements
AC Mains: 100 VAC to 120 VAC, 200 VAC to 240 VAC, 50 HZ to 60 Hz

Display type
Full VGA (640 x 480 pixels) transflective color LCD, 60 Hz update rate

Display dimensions (W x H, Diag.)
117 mm x 89 mm, 146 mm (4.62 in. x 3.49 in., 5.76 in.)

Pulser

Pulser
Tunable Square Wave

PRF
10 Hz to 2000 Hz in 10 Hz increments

Energy settings
100 V, 200 V, 300 V or 400 V

Pulse width
Adjustable from 25 ns to 5,000 ns (0.1 MHz) with PerfectSquare™ technology

Damping
50, 100, 200, 400 Ω

Receiver

Gain
0 to 110 dB

Maximum input signal
20 V p-p

Receiver input impedance
400 Ω ± 5%

Receiver bandwidth
0.2 MHz to 26.5 MHz at -3 dB

Digital filter settings
Thirty digital filter sets standard 
Seven ISO 22232-1:2020 compliant filters (0.2-10 MHz, 2.0-21.5 MHz, 8.0-26.5 MHz, 0.5-4 MHz, 0.2-1.2 MHz, 1.5-8.5 MHz, 5-15 MHz)

Rectification
Full-wave, Positive Half-wave, Negative Half-wave, RF

System linearity
Horizontal: ± 0.5% FSW

Resolution
0.25% FSH, amplifier accuracy ± 1dB

Reject
0 to 80% FSH with Visual Warning

Amplitude measurement
0 to 110% full screen height with 0.25% resolution

Measurement rate
Equivalent to PRF in all modes

Calibration
Automated calibration    Velocity, Zero Offset
Straight Beam (First Backwall or Echo-to-Echo)
Angle Beam (Soundpath or Depth)

Test modes
Pulse Echo, Dual, or Through Transmission

Units
Millimeters, inches, or microseconds

Range
3.36 mm to 13,388 mm (0.132 in. to 527.10 in.) @ 5,900 m/s (0.2320 in./μ)

Velocity
635 m/s to 15240 m/s (0.0250 in./µs to 0.6000 in./µs)

Zero offset
0 µs to 750 µs

Display delay
-59 mm to 13,401 mm (-2.320 in. to 526.97 in.) @ longitudinal velocity in steel

Refracted angle
0° to 90° in 0.1° increments

Gates

Measurement gates
2 fully independent gates for amplitude and TOF measurements

Gate start
Variable over entire displayed range

Gate width
Variable from Gate Start to end of displayed range

Gate height
Variable from 2 to 95% full screen height

Alarms
Positive and Negative Threshold, Minimum Depth (Gate 1 and Gate 2)

Measurements

Measurement display locations
5 locations available (manual or auto selection)

Gate (1, 2)
Thickness, Soundpath, Projection, Depth, Amplitude, Time-Of-Flight, Min./Max. Depth, Min./Max. Amplitude

Echo-to-Echo
Standard Gate 2-Gate 1, Optional IF Gate Tracking

Other measurements
Overshoot (dB) value for DGS/AVG, ERS (equivalent reflector size) for DGS/AVG, AWS D1.1/D1.5 A, B, C and D values, Reject Value, Echo to RefdB values

DAC/TCG
Standard

DAC points
Up to 50 points, 110 dB dynamic range

Special DAC modes
Custom DAC (up to 6 curves), 20-80% View

Curved surface correction
Standard OD or Bar correction for Angle Beam measurements

Corrosion (optional)
Zero-cross measurement algorithm, V-Path correction, Single or Echo-to-Echo, Encoded B-scan

Software Options

-EP650-TEMPLATE (Q1400002): Template Storage
-EP650-API5UE (Q1400003): API 5UE Flaw Sizing
-EP650-AVERAGE (Q1400004): Waveform Averaging
-EP650-IG (Q1400005): Interface Gate
-EP650-BEA (Q1400006): Backwall Echo Attenuator (BEA)
-EP650-CORRSN (Q1400001): Corrosion Module (includes encoded B-scan)

Optional Accessories

-600-BAT-L-2 (U8760058): Rechargeable lithium-ion battery
-EP4/CH (U8140055): Chest harness
-600-TC (U8780294): Transport case
-CBAS-10668-0060 (Q7790012): RS232 communication cable
-DSUB-HD15-6 (U8780333): Digital output cable
-600-C-VGA-5 (U8780298): VGA output cable
-MICROSD-ADP-2GB (U8779307): 2 GB microSD memory card
-600-SC-K (U8780334): Soft carrying case with pouch (knob version)
-600-SC-N (U8779879): Soft carrying case with pouch (navigation pad version)
-N600-EXTALM (U8780332): External alarm beeper
-CBAS-10669-0010 (Q7790008): Encoder cable for B-scan buggy (10 feet, other lengths available) 

Also you can check product : USED Olympus Epoch 650 Ultrasonic Flaw Detector

  • Availability: 18 In Stock
  • Model: Epoch 650
  • Brand: Olympus

Write Review

Note: Do not use HTML in the text.